Abu Dhabi City Municipality Smart Induction Streetlight Pilot Project Performance Report

2014-06-20

Abu Dhabi City Municipality Smart Induction Streetlight Pilot Project Performance Report

 

Location: Mussafah Abu Dhabi <in front of ADM building Mussafah branch>

 

Installed on: 3rd JUNE 2014
Total fixture quantity: 14pcs
Before - High Pressure Sodium lamp (Wattage x Qty): HPS 400w x 14pcs
After - Induction lamp (Wattage x Qty): model #AF-R15sf-S200C-5A1 (200w) X 14pc
Luminance data measured by:
Kun-Ling Tech Corp
Rm. 27, 7F., No.78, Sec. 2, Chongxin Rd., Sanchong Dist., New Taipei City 241, Taiwan (R.O.C.)
E-mail: service@kl-tech.com.tw  TEL: +886-2-2977-8165  FAX: +886-2-2977-8155
Measured date: 3rd JUNE 2014

After: Induction Lighting

 

Performance measurement - Zone 1: <cd/m2>

Zone 1: between pole #P25 and #P26

 

Zone 1 data measurement:  <no dimming>

 Roadway illumination min. requirement:   AVG >= 0.6 cd/m2  Uo >= 0.4   Ul >= 0.6

 

Zone 1 data measurement:  <dimming applied @80%>

  Roadway illumination min. requirement:   AVG >= 0.6 cd/m2  Uo >= 0.4   Ul >= 0.6

 

Performance measurement - Zone 2: <cd/m2>

Zone 2: between pole #P27 and #P28

 

Zone 2 data measurement:  <no dimming>

  Roadway illumination min. requirement:   AVG >= 0.6 cd/m2  Uo >= 0.4   Ul >= 0.6

 

Zone 2 data measurement:  <dimming applied @80%>

  Roadway illumination min. requirement:   AVG >= 0.6 cd/m2  Uo >= 0.4   Ul >= 0.6

 

 

Energy Savings Comparison

 

<No dimming>

 

Before

After

Light source

HPS

Induction

Energy consumption

440w *

220w *

Savings %

50%

* System wattage

 

<Dimming applied @80%>

 

Before

After

Light source

HPS

Induction

Energy consumption

440w *

176w *

Savings %

60%

* System wattage